Southwire 67847802, Metal Clad Cable 12 AWG 2C plus 2 Neutrals with Ground Solid Copper THHN Steel Armor
Description
Southwire 67847802 is a Duraclad® Type MC cable with two 12 AWG solid copper THHN/THWN phase conductors (brown and orange), two 12 AWG neutrals (gray-brown and gray-orange) and a 12 AWG green insulated ground under lightweight galvanized steel interlocked armor. Its conductors are rated 90°C dry, and the unjacketed cable is for dry, indoor locations.
Southwire 67847802 Technical Specs
Conductors and Insulation
| Conductor Size | 12 AWG |
|---|---|
| Phase Conductors | 2 |
| Neutral Conductors | 2 x 12 AWG |
| Conductor | Solid copper per ASTM B3 |
| Stranding | Solid |
| Conductor Colors | Phases: Brown, Orange; neutrals: Gray-Brown, Gray-Orange |
| Insulation | Polyvinyl chloride with nylon sheath, Type THHN/THWN |
| Insulation Thickness | 20 mils (0.51 mm) |
| Diameter Over Conductor | 0.08 in (0.20 cm) |
Grounding and Armor
| Grounding | Green PVC with nylon sheath Type THHN/THWN insulated ground conductor, 12 AWG |
|---|---|
| Ground Size | 1x12 |
| Binder | Mylar tape with print legend, wrapped around the assembly |
| Armor | Lightweight galvanized steel interlocked armor |
Dimensions and Weight
| Diameter Over Armor | 0.549 in (1.39 cm) |
|---|---|
| Approximate Weight | 277 lbs per 1,000 ft (412 kg/km) |
Ratings
| Temperature Rating | 90°C dry (Type THHN/THWN) |
|---|---|
| Location | Unjacketed; dry, indoor locations only per NEC 330.10(A)(10) |
Standards and Compliance
| ASTM B3 | Soft or Annealed Copper Wire |
|---|---|
| ASTM B8 | Concentric-Lay-Stranded Copper Conductors |
| UL 83 | Thermoplastic Insulated Wires and Cables |
| UL 1569 | Metal-Clad Cables |
| UL 1479 | Standard for Safety Fire Tests of Penetration Firestops |
| UL 1685 FT4 | Vertical-Tray Fire Propagation and Smoke Release Test |
| IEEE 1202 FT4 | Flame Test (70,000) BTU/hr Vertical Tray Test |
| RoHS-2 | European Directive 2011/65/EU |
| Buy American | Compliant with Buy American Requirements, found in 49 U.S.C. § 5323(j), when ordered as “Made in the USA Only!” |
| Meets or Exceeds | Federal Specification A-A59544 (formerly J-C-30B); NFPA 70 (National Electrical Code), Article 330 |
Southwire 67847802 Applications
- Branch and service power distribution in commercial, industrial, institutional and multi-residential buildings.
- Fished or embedded in plaster.
- Concealed or exposed installations.
- Environmental air-handling spaces per NEC 300.22(C).
- Places of assembly per NEC 518.4 and theaters per NEC 520.5.
- Cable tray and approved raceways.
- Under raised floors for information technology equipment conductors and cables per NEC Article 645.
- Class I Div. 2, Class II Div. 2 and Class III Div. 1.
- No anti-short bushing required.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.