Southwire 67963001, NM-B-PCS DUO Cable 10 AWG 2C Copper with Ground and 16/2 Signal Pair
Description
Southwire 67963001 is a 10 AWG copper Type NM-B-PCS DUO cable from Southwire's Romex Brand SIMpull line: 2 solid copper power conductors (black and white) with a 10 AWG bare copper ground, plus a 16 AWG control/signal pair of TFN insulated copper singles coloured pink and purple under their own light blue jacket. The cable is rated and all of its conductors at 600 volts.
Southwire 67963001 Technical Specs
Construction
| Power Conductor Size | 10 AWG |
|---|---|
| Power Conductors | 2 |
| Power Conductor Material | Solid copper per ASTM B3 |
| Power Conductor Colours | Black, White |
| Power Conductor Insulation | Polyvinyl chloride (PVC) with nylon sheath |
| Ground | 10 AWG solid soft drawn bare copper with kraft paper wrap |
| Control/Signal Conductors | 16 AWG copper, TFN insulated singles, coloured pink and purple |
| Control/Signal Jacket | Light blue, with a blue stripe over the control/signal component |
| Binder | Kraft paper |
| Overall Jacket | PVC, utilizing SIMpull Technology |
Dimensions and Weight
| Diameter Over Conductor (power) | 0.101 in (0.26 cm) |
|---|---|
| Insulation Thickness (power) | 25 mils (0.64 mm) |
| Jacket Thickness | 28 mils (0.71 mm) |
| Approx. Cross-Section (W x H) | 0.213 x 0.767 in (0.54 x 1.95 cm) |
| Copper Content Weight | 107 lbs/1000 ft (159 kg/km) |
| Approx. Total Weight | 169 lbs/1000 ft (251 kg/km) |
Ratings
| Voltage | 600 volts, all conductors |
|---|---|
| Circuit Separation | Complies with the Class 2/Class 3 circuit separation requirements of NEC 725.136(I)(1) and 725.136(I)(2) |
Standards
| ASTM B3 | Soft or Annealed Copper Wire |
|---|---|
| UL 719 | Nonmetallic-Sheathed Cables |
| RoHS-2 | European Directive 2011/65/EU |
| Federal Specification | A-A-59544 |
Southwire 67963001 Applications
- Used in residential wiring for SMART home applications such as 0-10V DC dimming controls for LED lighting.
- Suitable for both exposed and concealed work in dry locations, as specified in the National Electrical Code.
- May be run in air voids of masonry block or tile walls where those walls are not wet or damp locations.
- Do not use the control/signal component to make connections to 120V AC line voltage.