Southwire 89012299, Control Tray Cable 12 AWG 3C Copper XHHW-2 TC-ER 600V Black
Description
Southwire 89012299 is a 12 AWG 3-conductor control tray cable with Class B compressed bare copper conductors, cross-linked polyethylene (XLPE) Type XHHW-2 insulation and a black thermoplastic SOLONON® low smoke zero halogen (LSZH-TP) jacket. It is designated Type TC-ER and rated 600V. The conductors are colour coded black, red and blue.
Southwire 89012299 Technical Specs
Construction
| Conductor Size | 12 AWG |
|---|---|
| Number of Conductors | 3 |
| Conductor | 7 strands Class B compressed bare copper per ASTM B3 and ASTM B8 |
| Strands per Conductor | 7 |
| Insulation | Cross-linked polyethylene (XLPE), Type XHHW-2 |
| Conductor Colours | Black, Red, Blue, per ICEA S-58-679 Method 1 Table 2 |
| Filler | Polypropylene |
| Jacket | Black thermoplastic SOLONON low smoke zero halogen (LSZH-TP) |
| Type Designation | TC-ER |
Dimensions and Weight
| Insulation Thickness | 30 mils (0.76 mm) |
|---|---|
| Jacket Thickness | 45 mils (1.14 mm) |
| Approx. Overall Diameter | 0.412 in (1.05 cm) |
| Minimum Bend Radius | 1.6 in (4.06 cm) |
| Copper Weight | 61 lbs/1000 ft (91 kg/km) |
| Approx. Total Weight | 121 lbs/1000 ft (180 kg/km) |
Electrical and Thermal Ratings
| Voltage Rating | 600V |
|---|---|
| Conductor Temperature | 90°C normal operation in wet and dry locations; 130°C emergency overload; 250°C short circuit |
| Other | Sunlight resistant; silicone free |
| DC Resistance at 25°C | 1.662 |
| AC Resistance at 75°C | 2.002 |
| Allowable Ampacity, Raceway, 75°C | 25 |
| Allowable Ampacity, Raceway, 90°C | 30 |
Standards
| ASTM B3 | Soft or Annealed Copper Wire |
|---|---|
| ASTM B8 | Concentric-Lay-Stranded Copper Conductors |
| UL 44 | Thermoset-Insulated Wires and Cables |
| UL 1277 | Electrical Power and Control Tray Cables |
| UL 1685 | FT4 Vertical-Tray Fire Propagation and Smoke Release Test |
| ICEA S-58-679 | Control Cable Conductor Identification Method 1 Table 2 |
| ICEA S-73-532 | Standard for Control, Thermocouple Extension and Instrumentation Cables |
| ICEA S-95-658 (NEMA WC70) | Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy |
| IEEE 1202 FT4 | Flame Test (70,000) BTU/hr Vertical Tray Test |
Southwire 89012299 Applications
- Wet and dry areas, in conduits, ducts, troughs and cable trays.
- Direct burial, and aerial runs when supported by a messenger.
- Exposed runs as Type TC-ER per NEC 336.10.
- Class I, II, and III, Division 2 per NEC Article 501 and 502.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.