Southwire 89056389, Instrumentation Cable 16 AWG 12 Pair Copper Armored MC-HL 600V Black
Description
Southwire 89056389 is a 16 AWG armored instrumentation cable built from 12 twisted pairs (24 conductors) of 7-strand Class B bare copper. Each pair carries its own 100% coverage aluminum/polyester foil shield and drain wire, and the assembly is shielded again overall. A black PVC inner jacket and a rip cord sit beneath ARMOR-X® continuous impervious weld corrugated aluminum armor, and the outer jacket is black sunlight and moisture resistant PVC. The cable is rated 600V and -40°C to 90°C, Type MC-HL.
Rated for Class I Div I. Installations as outlined in NEC Article 330. Class I, II, and III, Division 1 and 2 per NEC Article 501, 502, and 503.
Southwire 89056389 Technical Specs
Conductors
| Conductor Size | 16 AWG |
|---|---|
| Number of Pairs | 12 |
| Total Conductors | 24 |
| Stranding | 7-strand, Class B |
| Conductor Material | Bare copper |
| Conductor Color Code | Black and white, with an alpha-numeric print on each pair |
| Insulation | Premium-grade PVC with a nylon covering |
| Insulation Thickness | 15 mils (0.38 mm) |
| Diameter Over Conductor | 0.056 in (0.14 cm) |
Shielding, Armor and Jacket
| Shielding | A 100% coverage aluminum/polyester foil shield over each pair with its own drain wire, plus a 100% coverage overall foil shield with a drain wire |
|---|---|
| Drain Wires | Tinned copper |
| Binder | Mylar binder |
| Rip Cord | Under the jacket, for ease of removal |
| Inner Jacket | Black PVC |
| Armor | ARMOR-X® continuous impervious weld corrugated aluminum armor |
| Jacket | Black sunlight and moisture resistant PVC |
Dimensions and Weight
| Approximate Outside Diameter | 1.346 in (3.42 cm) |
|---|---|
| Diameter Over Armor | 1.22 in (3.10 cm) |
| Approximate Weight | 789 lbs/1000 ft (1174 kg/km) |
| Minimum Bend Radius | 9.4 in (23.88 cm) |
Ratings and Standards
| Voltage Rating | 600V |
|---|---|
| Temperature Range | -40°C to 90°C |
| DC Resistance at 25°C, per Conductor | 4.181 ohms/1000 ft |
| Type Designation | Type MC-HL |
| Standards | ASTM B8 Concentric-Lay-Stranded Copper Conductors; ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire; UL 66 Fixture Wire; UL 83 Thermoplastic Insulated Wires and Cables; UL 1569 Metal-Clad Cables; UL 2225; IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test; EPA 40 CFR, Part 26, Subpart C heavy metals per Table 1, TCLP method |
Southwire 89056389 Applications
- Process control and instrumentation service.
- Control circuits that operate and interconnect protective and signaling devices.
- General use in manufacturing plants and industrial or commercial distribution systems.
- Cable trays, raceways and conduit, aerial runs supported by a messenger, and direct burial.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.