Southwire 89057599, Instrumentation Cable 18 AWG 12 Pair Copper Armored MC-HL 600V Black
Description
Southwire 89057599 is an 18 AWG armored instrumentation cable with 12 twisted pairs (24 conductors) of 7-strand Class B bare copper, each pair under its own 100% coverage aluminum/polyester foil shield and drain wire, with a second overall foil shield and drain around the Mylar-bound core. A black PVC inner jacket and rip cord sit beneath ARMOR-X® continuous impervious weld corrugated aluminum armor, finished with a black sunlight and moisture resistant PVC outer jacket. It is designated Type MC-HL ARMOR-X per UL 1569 and rated 600V and -40°C to 90°C.
Rated for Class I Div I. For uses in Class I, II, and III, Division 1 and 2 per NEC Article 501, 502, and 503.
Southwire 89057599 Technical Specs
Conductors and Insulation
| Conductor Size | 18 AWG |
|---|---|
| Number of Pairs | 12 |
| Total Conductors | 24 |
| Conductor | Class B stranded bare copper per ASTM B3 and B8, 7-strand |
| Diameter Over Conductor | 0.045 in (0.11 cm) |
| Insulation | PVC plus nylon |
| Insulation Thickness | 15 mils (0.38 mm) |
| Pair Color Code | Black/White with alpha-numeric print on each pair |
| DC Resistance at 25°C, per Conductor | 6.669 ohms/1000 ft |
Shielding, Armor and Jacket
| Pair Shield | 100% coverage aluminum/polyester foil with an individual drain wire |
|---|---|
| Overall Shield | 100% coverage aluminum/polyester foil with a drain wire |
| Drain Wires | Tinned copper |
| Binder | Mylar |
| Inner Jacket | Black PVC, with rip cord under the jacket |
| Armor | ARMOR-X® continuous impervious weld corrugated aluminum |
| Outer Jacket | Black PVC, sunlight and moisture resistant |
Dimensions and Weight
| Approximate Outside Diameter | 1.146 in (2.91 cm) |
|---|---|
| Diameter Over Armor | 1.02 in (2.59 cm) |
| Approximate Weight | 560 lbs/1000 ft (833 kg/km) |
| Minimum Bend Radius | 8.0 in (20.32 cm) |
Ratings and Standards
| Voltage Rating | 600V |
|---|---|
| Temperature Range | -40°C to 90°C |
| Type Designation | Type MC-HL |
| Standards | ASTM B8 Concentric-Lay-Stranded Copper Conductors; ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire; UL 66 Fixture Wire; UL 83 Thermoplastic Insulated Wires and Cables; UL 1569 Metal-Clad Cables; UL 2225; IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test; EPA 40 CFR, Part 26, Subpart C heavy metals per Table 1, TCLP method |
Southwire 89057599 Applications
- Process control and instrumentation installations as outlined in NEC Article 330.
- Control circuits that operate and interconnect protective and signaling devices.
- General use in manufacturing, industrial and commercial distribution systems.
- Cable trays, raceways, conduit, aerial runs supported by a messenger, and direct burial.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.