Southwire 89060702, Type AC Armored Cable 8 AWG 2C Stranded Copper THHN
Description
Southwire 89060702 is an Armorlite® Type AC armored cable with two 8 AWG 19-strand combination unilay copper conductors, insulated Type THHN/THWN and colored black and white. Each conductor is individually wrapped in a moisture-resistant, flame-retardant paper covering, and a solid 16 AWG aluminum bond wire runs under the aluminum interlocked armor. It is for dry locations only, and anti-short bushings are required.
Southwire 89060702 Technical Specs
Conductors and Insulation
| Conductor Size | 8 AWG |
|---|---|
| Number of Conductors | 2 |
| Conductor | 19-strand combination unilay copper per ASTM B3 and B787 |
| Conductor Colors | Black, White |
| Insulation | Polyvinyl chloride with nylon sheath, Type THHN/THWN |
| Insulation Thickness | 35 mils (0.89 mm) |
| Diameter Over Conductor | 0.143 in (0.36 cm) |
| Paper Covering | Moisture-resistant, flame-retardant, over each conductor |
Bonding and Armor
| Bond Wire | Solid 16 AWG 8000 series aluminum per ASTM B800 |
|---|---|
| Armor | Aluminum interlocked armor |
Dimensions and Weight
| Diameter Over Armor | 0.790 in (2.01 cm) |
|---|---|
| Approximate Weight | 243 lbs per 1,000 ft (362 kg/km) |
Ratings
| Conductor Temperature Rating | 90°C dry, Type THHN/THWN |
|---|---|
| Location | Dry locations only |
| Anti-Short Bushing | Required |
Standards
| ASTM B3 | Soft or annealed copper wire |
|---|---|
| ASTM B787 | 19 wire combination unilay-stranded copper conductors |
| UL 83 | Thermoplastic insulated wires and cables |
| UL 4 | Armored cables |
| RoHS-2 | European Directive 2011/65/EU |
| Buy American | Compliant with Buy American Requirements, found in 49 U.S.C. § 5323(j), when ordered as “Made in the USA Only!” |
| Federal Specification | Meets or exceeds A-A59544 (formerly J-C-30B) |
| NFPA 70 (NEC) | Meets or exceeds Article 320 |
Southwire 89060702 Applications
- Feeder power distribution in commercial, industrial, institutional and multi-residential buildings.
- Fished installations, or embedded in plaster.
- Concealed or exposed runs.
- Environmental air-handling spaces per NEC 300.22(C).
- Cable tray and approved raceways.
- Under raised floors, for information technology equipment conductors and cables per NEC Article 645.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.