Southwire 89061589, Armored Cable 2 AWG 3C Copper 2.4 kV Yellow
Southwire · MPN 89061589
Description
Southwire 89061589 is a 2 AWG three-conductor medium-voltage armored power cable rated 2.4 kV, 100% insulation level. Its three 7-strand bare copper conductors carry 90 mils of EPR over a semi-conducting conductor shield, and three 10 AWG bare copper grounding conductors run with them. ARMOR-X® continuous corrugated welded armor and a yellow polyvinyl chloride (PVC) outer jacket complete the cable.
Southwire 89061589 Technical Specs
Conductors & Insulation
| Conductor Size | 2 AWG |
|---|---|
| Number of Conductors | 3 |
| Strands per Conductor | 7 |
| Conductor | Class B compressed stranded bare copper per ASTM B3 and ASTM B8 |
| Insulation | Ethylene propylene rubber (EPR) |
| Insulation Thickness | 90 mils (2.29 mm) |
| Diameter Over Conductor | 0.282 in (0.72 cm) |
| Diameter Over Insulation | 0.495 in (1.26 cm) |
Shielding
| Conductor Shield | Semi-conducting cross-linked copolymer |
|---|
Grounding, Armor & Jacket
| Grounding Conductors | Three 10 AWG Class B compressed stranded bare copper grounding conductors |
|---|---|
| Filler | Wax paper |
| Binder | Polypropylene tape |
| Armor | ARMOR-X® continuous corrugated welded armor |
| Diameter Over Armor | 1.430 in (3.63 cm) |
| Outer Jacket | Yellow polyvinyl chloride (PVC) |
| Jacket Thickness | 70 mils (1.78 mm) |
Dimensions & Weight
| Approximate Outside Diameter | 1.570 in (3.99 cm) |
|---|---|
| Approximate Weight | 1432 lbs/1000 ft (2131 kg/km) |
| Maximum Pull Tension | 1592 lbs (722.12 kg) |
| Minimum Bend Radius | 10.9 in (27.69 cm) |
Ratings & Compliance
| Voltage Rating | 2.4 kV, 100% insulation level |
|---|---|
| Operating Temperatures | 105°C normal operation; 130°C emergency overload; 250°C short circuit |
| Cold Bend | -50°C |
| Standards | ASTM B3 Soft or Annealed Copper Wire; ASTM B8 Concentric-Lay-Stranded Copper Conductors; UL 1072 Medium-Voltage Power Cables; ICEA S-96-659 (NEMA WC 71) 2001-5000 V Nonshielded Cables; IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test |
| Made in America | Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661 |
Southwire 89061589 Applications
- Wet and dry areas, conduits, ducts, troughs and trays, as well as direct burial or concrete encasement.
- Suitable for variable frequency drive (VFD) applications.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.