Southwire 89067699, Control Tray Cable 14 AWG 4C Copper XHHW-2 TC 600V Black
Description
Southwire 89067699 is a 14 AWG 4-conductor control tray cable with Class B compressed copper conductors, cross-linked polyethylene (XLPE) Type XHHW-2 insulation and a black thermoplastic chlorinated polyethylene (CPE-TP) jacket. It is Type TC and rated 600V.
Southwire 89067699 Technical Specs
Construction
| Conductor Size | 14 AWG |
|---|---|
| Number of Conductors | 4 |
| Strands | 7 |
| Conductor | Class B compressed copper per ASTM B3 and ASTM B8 |
| Insulation | Cross-linked polyethylene (XLPE), Type XHHW-2 |
| Conductor Colours | Black, Red, Blue, Orange |
| Filler and Binder | Polypropylene filler |
| Jacket | Thermoplastic chlorinated polyethylene (CPE-TP) |
| Jacket Colour | Black |
| Type | TC |
Dimensions and Weight
| Insulation Thickness | 30 mils (0.76 mm) |
|---|---|
| Jacket Thickness | 45 mils (1.14 mm) |
| Approx. Overall Diameter | 0.409 in (1.04 cm) |
| Minimum Bend Radius | 1.6 in (4.06 cm) |
| Copper Weight | 51 lbs/1000 ft (76 kg/km) |
| Approx. Weight | 111 lbs/1000 ft (165 kg/km) |
Electrical and Environmental Ratings
| Voltage Rating | 600V |
|---|---|
| Conductor Temperature | 90°C normal operation in wet and dry locations; 130°C emergency overload; 250°C short circuit |
| DC Resistance at 25°C | 2.631 |
| AC Resistance at 75°C | 3.170 |
| Allowable Ampacity, Raceway, 75°C | 16 |
| Allowable Ampacity, Raceway, 90°C | 20 |
| Other | sunlight resistant; silicone free |
Standards
| ASTM B3 | Soft or Annealed Copper Wire |
|---|---|
| ASTM B8 | Concentric-Lay-Stranded Copper Conductors |
| UL 44 | Thermoset-Insulated Wires and Cables |
| UL 1277 | Electrical Power and Control Tray Cables |
| UL 1685 FT4 | Vertical-Tray Fire Propagation and Smoke Release Test |
| ICEA S-58-679 | Control Cable Conductor Identification Method 1 Table 2 |
| ICEA S-73-532 | Standard for Control, Thermocouple Extension and Instrumentation Cables |
| ICEA S-95-658 (NEMA WC70) | Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy |
| IEEE 1202 FT4 | Flame Test (70,000) BTU/hr Vertical Tray Test |
Southwire 89067699 Applications
- Wet and dry locations, in conduits, ducts, troughs and cable trays.
- Direct burial, and aerial installation supported by a messenger.
- Class I, II, and III, Division 2 per NEC Article 501 and 502.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.