Southwire 95237499, Armored Cable 500 KCMIL 4C Copper XHHW-2 600 V
Description
Southwire 95237499 is a 500 KCMIL four-conductor armored power cable rated 600 V. Its four 37-strand bare copper conductors carry 65 mils of XHHW-2 XLPE, and three 1 AWG bare copper grounding conductors run with them. Aluminum interlocked armor (AIA) and a polyvinyl chloride (PVC) outer jacket complete the cable. Part of the 600 Volt Type MC power cable line.
Southwire 95237499 Technical Specs
Conductors & Insulation
| Conductor Size | 500 KCMIL |
|---|---|
| Number of Conductors | 4 |
| Strands per Conductor | 37 |
| Conductor | Class B compressed stranded bare copper per ASTM B3 and ASTM B8 |
| Insulation | Cross-linked polyethylene (XLPE), Type XHHW-2 |
| Insulation Thickness | 65 mils (1.65 mm) |
| Diameter Over Conductor | 0.789 in (2.00 cm) |
Grounding, Armor & Jacket
| Grounding Conductors | Three 1 AWG Class B compressed stranded bare copper grounding conductors, sized together to 50% of the phase conductor |
|---|---|
| Filler | Paper |
| Binder | Polypropylene tape |
| Armor | Aluminum interlocked armor (AIA) |
| Diameter Over Armor | 2.504 in (6.36 cm) |
| Outer Jacket | Polyvinyl chloride (PVC) |
| Jacket Thickness | 75 mils (1.91 mm) |
Dimensions & Weight
| Approximate Outside Diameter | 2.654 in (6.74 cm) |
|---|---|
| Approximate Weight | 8284 lbs/1000 ft (12328 kg/km) |
| Maximum Pull Tension | 12800 lbs (5805.98 kg) |
| Minimum Bend Radius | 18.6 in (47.24 cm) |
Ratings & Compliance
| Voltage Rating | 600 V |
|---|---|
| Operating Temperatures | 90°C normal operation in wet and dry locations; 130°C emergency overload; 250°C short circuit |
| Location Rating | Class I, II, and III, Division 2 per NEC Article 501 and 502 |
| Silicone | Silicone free |
| Standards | ASTM B3 Soft or Annealed Copper Wire; ASTM B8 Concentric-Lay-Stranded Copper Conductors; UL 44 Thermoset-Insulated Wires and Cables; UL 1569 Metal-Clad Cables; UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test; ICEA S-58-679 Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE); ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy |
Southwire 95237499 Applications
- Wet and dry areas, conduits, ducts, troughs and trays, along with direct burial and aerial runs supported by a messenger.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.