Southwire 95313301, Control Tray Cable 12 AWG 12C Copper XHHW-2 TC-ER 600V Black
Description
Southwire 95313301 is a 12 AWG, 12-conductor control tray cable with Class B compressed bare copper per astm b3 and b8 conductors, cross-linked polyethylene (XLPE) Type XHHW-2 insulation and a black polyvinyl chloride (PVC) jacket. It carries the Type TC-ER designation and a 600V rating.
Southwire 95313301 Technical Specs
Construction
| Conductor Size | 12 AWG |
|---|---|
| Number of Conductors | 12 |
| Strands per Conductor | 7 |
| Conductor | Class B compressed bare copper per ASTM B3 and B8 |
| Insulation | Cross-linked polyethylene (XLPE), Type XHHW-2, VW-1 rated |
| Conductor Identification | Black, Red, Blue, Orange, Yellow, Brown, Red-Black Stripe, Blue-Black Stripe, Orange-Black Stripe, Yellow-Black Stripe, Brown-Black Stripe, Black-Red Stripe |
| Filler and Binder | Polyester flat thread binder tape |
| Jacket | Polyvinyl chloride (PVC) |
| Jacket Colour | Black |
| Jacket Properties | Sunlight resistant; silicone free |
| Type Designation | TC-ER |
Dimensions and Weight
| Insulation Thickness | 30 mils (0.76 mm) |
|---|---|
| Jacket Thickness | 60 mils (1.52 mm) |
| Approx. Overall Diameter | 0.738 in (1.87 cm) |
| Minimum Bend Radius | 3.0 in (7.62 cm) |
| Copper Weight | 243 lbs/1000 ft (362 kg/km) |
| Approx. Total Weight | 404 lbs/1000 ft (601 kg/km) |
Electrical and Thermal Ratings
| Voltage Rating | 600V |
|---|---|
| Conductor Temperature | 90°C normal operation in wet and dry locations; 130°C emergency overload; 250°C short circuit |
| DC Resistance at 25°C (ohms/1000 ft) | 1.662 |
| AC Resistance at 75°C (ohms/1000 ft) | 2.002 |
| Allowable Ampacity, Raceway, 75°C | 12 |
| Allowable Ampacity, Raceway, 90°C | 15 |
Standards
| ASTM B3 | Soft or Annealed Copper Wire |
|---|---|
| ASTM B8 | Concentric-Lay-Stranded Copper Conductors |
| UL 44 | Thermoset-Insulated Wires and Cables |
| UL 44 VW-1 | Vertical flame test on individual conductors |
| UL 1277 | Electrical Power and Control Tray Cables |
| UL 1685 FT4 | Vertical-Tray Fire Propagation and Smoke Release Test |
| ICEA S-58-679 | Control Cable Conductor Identification Method 1 Table 2 |
| ICEA S-73-532 | Standard for Control, Thermocouple Extension and Instrumentation Cables |
| ICEA S-95-658 (NEMA WC70) | Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy |
| IEEE 1202 FT4 | Flame Test (70,000) BTU/hr Vertical Tray Test |
Southwire 95313301 Applications
- Wet and dry areas, in conduits, ducts, troughs and cable trays.
- Direct burial, and aerial installation supported by a messenger.
- Class I, II and III, Division 2 per NEC Article 501 and 502.
- Exposed runs (TC-ER) per NEC 336.10.
- Jacket extruded over the core as a gas/vapor-tight polymeric sheath per NEC Sections 501.15(D) and 501.15(E); further sealing may still be needed in a classified location, as the NEC describes.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.