Southwire 95595599, Control Tray Cable 10 AWG 3C Copper XHHW-2 TC-ER 1000V Black
Description
Southwire 95595599 is a 10 AWG, 3-conductor control tray cable with Class B compressed bare copper per astm b3 and astm b8 conductors, cross-linked polyethylene (XLPE) Type XHHW-2 insulation and a black polyvinyl chloride (PVC) jacket. It carries the Type TC-ER designation and a 1000V rating. A 10 AWG green-insulated grounding conductor runs with the 3 circuit conductors.
Southwire 95595599 Technical Specs
Construction
| Conductor Size | 10 AWG |
|---|---|
| Number of Conductors | 3 |
| Strands per Conductor | 7 |
| Conductor | Class B compressed bare copper per ASTM B3 and ASTM B8 |
| Insulation | Cross-linked polyethylene (XLPE), Type XHHW-2 |
| Conductor Identification | Black, Red, Blue |
| Grounding Conductor | One 10 AWG Class B compressed stranded copper grounding conductor with green insulation, in addition to the 3 circuit conductors |
| Filler and Binder | Polypropylene filler |
| Jacket | Polyvinyl chloride (PVC) |
| Jacket Colour | Black |
| Jacket Properties | Sunlight resistant; silicone free |
| Type Designation | TC-ER |
Dimensions and Weight
| Insulation Thickness | 30 mils (0.76 mm) |
|---|---|
| Jacket Thickness | 45 mils (1.14 mm) |
| Approx. Overall Diameter | 0.547 in (1.39 cm) |
| Minimum Bend Radius | 2.2 in (5.59 cm) |
| Copper Weight | 129 lbs/1000 ft (192 kg/km) |
| Approx. Total Weight | 224 lbs/1000 ft (333 kg/km) |
Electrical and Thermal Ratings
| Voltage Rating | 1000V |
|---|---|
| Conductor Temperature | 90°C normal operation in wet and dry locations; 130°C emergency overload; 250°C short circuit |
| DC Resistance at 25°C (ohms/1000 ft) | 1.040 |
| AC Resistance at 75°C (ohms/1000 ft) | 1.253 |
| Allowable Ampacity, Raceway, 75°C | 35 |
| Allowable Ampacity, Raceway, 90°C | 40 |
Standards
| ASTM B3 | Soft or Annealed Copper Wire |
|---|---|
| ASTM B8 | Concentric-Lay-Stranded Copper Conductors |
| UL 44 | Thermoset-Insulated Wires and Cables |
| UL 1277 | Electrical Power and Control Tray Cables |
| UL 1685 | Vertical-Tray Fire Propagation and Smoke Release Test |
| ICEA S-58-679 | Control Cable Conductor Identification Method 1 Table 2 |
| ICEA S-73-532 | Standard for Control, Thermocouple Extension and Instrumentation Cables |
| ICEA S-95-658 (NEMA WC70) | Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy |
| IEEE 1202 FT4 | Flame Test (70,000) BTU/hr Vertical Tray Test |
| VW-1 | Vertical-Wire Flame Test |
Southwire 95595599 Applications
- Wet and dry areas, in conduits, ducts, troughs and cable trays.
- Direct burial, and aerial installation supported by a messenger.
- Class I, II and III, Division 2 per NEC Article 501 and 502.
- Exposed runs (TC-ER) per NEC 336.10.